How to: Present iSCSI storage from a NetApp vfiler (7-Mode)

As part of a recent data migration I had to enable a vfiler to allow iSCSI traffic as a number of virtual machines in the environment require block storage for clustering reasons. The vfiler already presents via NFS and iSCSI. As this is a test environment I’ve decided to put iSCSI on the same link as the NFS and CIFS. I know this is not normal best practice but given that the vLANs are already in place and that this is a test environment I decided to use the same IP address range. The servers accessing the iSCSI LUNs don’t have access to CIFS or to any NFS mounts already so there should be no traffic cross-over. So onto the steps to set it up:

Step 1: Allow iscsi protocol and RSH on vfiler (at vfiler0)

Check the status of the vfiler using the command

vfiler status -a tenant_vfiler
tenant_vfiler running
 ipspace: tenant_vfiler_NFS_CIFS
 IP address: 192.168.2.1 [a1a-107]
 IP address: 192.168.2.2 [a1a-107]
 Path: /vol/tenant_vfiler_vol0 [/etc]
 Path: /vol/nfs03
 Path: /vol/nfs04
 Path: /vol/nfs02
 Path: /vol/nfs01
 Path: /vol/cifs01
 Path: /vol/iso01
 Path: /vol/iscsi_test
 UUID: 93c62e36-4e76-11e4-8721-123478563412
 Protocols allowed: 7
Disallowed: proto=rsh
 Allowed: proto=ssh
 Allowed: proto=nfs
 Allowed: proto=cifs
Disallowed: proto=iscsi
 Allowed: proto=ftp
 Allowed: proto=http
 Protocols disallowed: 2

Next run the command:

vfiler allow tenant_vfiler proto=iscsi
vfiler allow tenant_vfiler proto=rsh

Step 2: Start iSCSI protocol on vfiler (at apaubmwvfi01)

vfiler context tenant_vfiler
iscsi start

Step 3: Create a new volume at vfiler0

vfiler context vfiler0
vol create iscsi_test_vol -s 20g

Step 4: Migrate the volume to apaubmwvfi01 and log into the vfielr to check the volume status

vfiler add tenant_vfiler /vol/iscsi_test
vfiler context tenant_vfiler
vol status

Step 5: Set priv advanced and modify the exports to the correct settings as below

To modify the exports read the current /exports and write it back. Once done run the exportsfs -av command to push the changes out

rdfile /vol/tenant_vfiler_vol0/etc/exports
/vol/nfs01 -sec=sys,rw=192.168.1.0/24,anon=0
/vol/nfs02 -sec=sys,rw=192.168.1.0/24,anon=0
/vol/nfs03 -sec=sys,rw=192.168.1.0/24,anon=0
/vol/nfs04 -sec=sys,rw=192.168.1.0/24,anon=0
/vol/iso01 -sec=sys,rw=192.168.1.0/24,anon=0
/vol/iscsi_test -sec=sys,rw=192.168.1.0/24,anon=0
vfiler run tenant_vfiler exportfs -av

Step 6: Create a lun from the volume (iscsi_test)

vfiler run tenant_vfiler lun create -s 10g -t windows2008 /vol/iscsi_test/iscsi_lun

Step 7: Change filer and run lun show

lun_show

Step 8: Verify iSCSI network within VMware has been assigned to the VM
iSCSI network
Step 9: Enable iSCSI Initiator – grab the iqn

iSCSI initiator iqn

Step 10: Create an igroup with the iqn of the server

igroup create -t Windows2008 ds_iscsi 
igroup add ds_iscsi iqn.1991-05.com.microsoft:microsoft:server.domain.com

Step 11: map the lun to the group name

map_lun_to_group

Step 12: run lun show -m to check the mapping

lun_show_mapping

Step 13: Run a quick connect to the IP address of the controller

iscsi_quick_connect

And now your disk should appear in the disk manager on the server. It’s not too different to setting up a normal iSCSI connection but RSH must be enabled otherwise it can’t tunnel the iSCSI  request to the vfiler iqn target.

NetApp – Create a new volume on vFiler (7-mode)

I had to create a new volume on a vfiler recently. This is a fairly straight-forward tasks for long term NetApp admins but I thought I’d write up the process for the next time that I forget. In this example the vfiler already exists and has been exported on a different subnet than the root vfiler, vfiler0. If you’re new to vfilers then you’ll immediately notice that once you change the vfiler context to the vfiler you want to add a volume to that you don’t have the option to create a new volume. The new volume needs to be created at the root vfiler level and then assigned to the vfiler you wish. In this example I am create a new ISO datastore on a vfiler context so that one of our tenants can have their own ISO datastore. We could present out the ISO datastore from vfiler0 but that would break the security model we worked hard to put in place.

The first thing to do is change the vfiler context and then run the vol command. You will see from this that it’s not possible to create the volume directly on the vfiler.

vfiler context <tenant-vfiler>
tenant-vfiler@NTAPcontroller> vol
The following commands are available; for more information
type "vol help "
offline             options             restrict            status
online
tenant-vfiler@NTAPcontroller> vol create iso01 aggr1 200g
vol: No such command "create".
The following commands are available; for more information
type "vol help "
offline             options             restrict            status
online

So go back to the parent vfiler, vfiler0, and then create the new volume. From there you can add it to the tenant-vfiler. Before transferring the volume to the tenant-vfiler I have also changed the options to make the volume thin provisioned using the “guarantee none” setting and also set fractional_reserve to 0. The commands used to create the new volume, modify the settings and add it to the tenant-vfiler were:

tenant-vfiler@NTAPcontroller> vfiler context vfiler0
NTAPcontroller> vol create iso01 -s volume aggr1 200g
NTAPcontroller> vol options iso01 guarantee none
NTAPcontroller> vol options iso01 fractional_reserve 0
NTAPcontroller> vol status iso01
  Volume State          Status            Options
  iso01 online          raid_dp, flex     create_ucode=on, convert_ucode=on,
                        mirrored  guarantee=none, fractional_reserve=0
                        64-bit
                        Volume UUID: 0df82cec-fdb8-11e4-a27a-123478563412
                Containing aggregate: 'aggr1'

NTAPcontroller> vfiler add tenant-vfiler /vol/iso01
WARNING: reassigning storage to another vfiler does not change the security information on that storage. If the security domains are not identical, unwanted access may be permitted, and wanted access may be denied.
Tue May 19 09:47:47 EST [NTAPcontroller:cmds.vfiler.path.move:notice]: Path /vol/iso01 was moved to vFiler unit "tenant-vfiler".
Tue May 19 09:47:47 EST [NTAPcontroller:export.auto.update.disabled:warning]: /etc/exports was not updated for iso01 when the vol destroy command was run. Please either manually update /etc/exports or copy /etc/exports.new to it.
NTAPcontroller>